Top

HEATERS & TORCHES

HEATER, INDIRECT TOW 600k Btu

Where to find HEATER, INDIRECT TOW 600k Btu in Whistler

Image for reference only
Actual item may look different
Click on image for larger view

Where to find HEATER, INDIRECT TOW 600k Btu in Whistler

Click on above thumbnails for alternate view

Manufacturer: CAMPO

Model: 600D TOWABLE

Daily: $250.00

Weekly: $749.00

Quantity: for a period of  
day(s)   week(s)  


Additional Information

100 US Gallon Fuel Tank, 32 hr. Run Time

Specifications:
BLAZE 600D TURBO
 Input BTU/h: 588,000
 Indirect Oil Fired
 Beckett Burner
 240 ̊F + Heat Rise
 Ductability: 150 ft. (Turbo)
 Fuel Tank: 100 US Gallons (380 L)
 Whisper Quiet Operation
 Air Volume: 5,500 CFM
 Up to 4" of Static pressure
 Recirculating Capabilities
 Thermostat Operation
 Genysis Primary Controller
 Digital Panel Mounted Voltmeter
 Redundant Fail Safe Control System
 Oil pressure gauge, Spin-off Filter
 Dimensions: 76.7" X 31" X 57.6"
 Full Load Amps: 11.5
 Power Supply: 120 Volt, 15 A
 Air Outlets: Two 12”
 Air Inlets: 1 X 16”
 Stainless Steel Heat Exchanger
 CSA/UL Approved

With features like 6,500 CFM, ductable to 150 feet with a full load power consumption of a mere 11.5 amps, it’s not surprising why the Blaze 600D Turbo boasts the highest performance level in its class. Capable of 3″ of static pressure, it comes equipped with Whisper Quiet Operation, 240° F Heat Rise and Air Recirculating Capabilities.

Designed to meet the particular needs of the rental market, the low amp draw (11.5 A) and high static capabilities makes the Turbo adaptable to unpredictable environments. The sleek and compact design (76.7” x 31” x 57.6”) combines efficiency with high performance making the 600 Turbo adaptable to various heating and drying applications. Rental rugged and designed for durability.

We continue to listen and innovate, one of the greatest challenges for portable heaters is power and power quality. Overloaded temporary power systems on job sites, undersized or overly long extension cords all make for problems. Our answer: the latest generation Turbo heaters.

Kinked ducting or too much ducting can also create havoc on your heater and result in increased service calls. The latest generation of 400/600K BTU Turbo heaters are able to be ducted up to 150ft, therefore reducing the amount of service related calls due to overheating.

Also check the following item(s) related to the above:
* Prices are subject to change.
* Please call us with any questions about our heater indirect tow 600k btu in Whistler BC, serving Squamish, Pemberton, and the Sea-to-Sky Corridor.